Profile Editor: ISDN Specifications

Interface init: Selection of the physical interface type.

  • E1: ISDN PRI CEPT Trunk E1
  • T1: ISDN PRI North-American Trunk T1
  • S0/T0: ISDN BRI S/T
  • U: ISDN BRI U 2B1Q
  • Options: The options for the physical interface.

    Emulation mode: The behaviour of the Clarinet interface.

  • Monitor: Both directions of the Clarinet interface are monitored in the same time with a common time-stamp.
  • User: Clarinet interface emulates a User side of a BRI/PRI interface. The monitoring function is simultaneously active.
  • Network: Clarinet interface emulates a Network side of a BRI/PRI interface. The monitoring function is simultaneously active.
  • SL Protocol: ISDN Q931 national implementation:

  • ETSI Basic, ETSI Primary: ETSI Specification ETS 300 403-7
  • VN3-Basic, VN3-Primary: FRANCE TELECOM VN3
  • VN4-Basic, VN4-Primary: FRANCE TELECOM VN4
  • ISDN2-Basic, ISDN30-Primary: BRITISH TELECOM
  • SWISSNET2-Basic, SWISSNET2-Primary: SWISS PTT
  • V1-Basic, V1-Primary: BELGIAN RTT
  • E-DSS1-Basic, E-DSS1-Primary: DBP TELEKOM
  • DT Basic, DT Primary: DANISH TELECOM
  • NORDTEL-Basic, NORDTEL-Primary: NORDTEL
  • 5ESS-Basic, 5ESS-Primary: AT&T
  • NI-Basic, NI-Primary: BELLCORE
  • DMS-100-Basic, DMS-100-Primary: NORTHERN
  • Interface spec... Configuration of the physical interface.

    Emulator config... When Clarinet emulates a User or Network side, the specification of the parameters of the signalling protocol (Q921, Q931).

    Signalling Behaviour: Configuration of the simulation on SL:

    • Generator: Specification of the outgoing communications of the ISDN Call simulator.
      • No. The Generator behaviour is de-activated. No call or connection will be launched during the profile execution.
      • Yes. The Generator behaviour is activated.
    • Responder: Specification of the incoming communications of the ISDN Call simulator.
      • No. The Responder behaviour is limited to marked items '(emu)' relating to Incoming call accepted - Call establishment or Incoming call rejected.
      • Yes. The Responder behaviour is activated.
    • Miscellaneous: Specification of various messages to be sent manually to initialise the related service.
    • X25 call simulator: Specification of the X25 Call simulation on SL.
    • User Program: The simulation behaviour is carried out by the execution of a user-developed program in C language.
    • TTCN User Program: Simulation defined by Executable Test Suites resulting from TTCN compilation.

    Data Behaviour: Configuration of the simulation on DL:

    • Call simulator: Specification of the Data call simulation on DL by an automatic simulator.
    • User Program: The simulation behaviour is carried out by the execution of an user-developed program in C language.
    • TTCN User Program: Simulation defined by Executable Test Suites resulting from TTCN compilation.

     