ISDN Signalling Behaviour: Responder
Note: The items marked (emu) are relevant to the Q931 emulator
behaviour.
Accept incoming calls (emu): Configuration
of the Responder behaviour.
IE(s)... Optional specification of IE which must be included in
the incoming SETUP message for the call to be accepted.
Incoming call rejected
Call clearing (emu): With the following steps
in sequence:
- Send RELEASE COMPLETE...
Access to editing the attached buffer of IE(s).
Message transmission if validation
No: The related message will not be sent.
No response to incoming SETUP (ETSI 5.2.2a behaviour).
Yes: The message will be sent in sequence.
Response to incoming SETUP (ETSI 5.2.2b behaviour).
Incoming Call Accepted - Call Establishment
With the following steps in sequence:
- Send message: Validation of the transmission of the
related message.
No: The message will not be sent.
Yes: The message will be sent in sequence.
- If no SC: Only for SETUP ACK.
The message will be sent in sequence only if the Sending
Complete IE is not present in the incoming SETUP.
- Send SETUP ACK... (emu)
Message transmission if validation.
Access to editing the attached buffer of IE(s).
- Send CALL PROC... (emu)
Message transmission if validation.
Access to editing the attached buffer of IE(s).
- Send PROGRESS... (emu)
Message transmission if validation.
Access to editing the attached buffer of IE(s).
- Send ALERTING... (emu)
Message transmission if validation.
Access to editing the attached buffer of IE(s).
- Delay before CONNECT. Delay before sending the CONNECT message
(if to be sent), starting from the reception of the incoming SETUP message.
An empty field means an infinite value of time.
If the Outgoing call active source is used, the delay
is before the generation of the outgoing SETUP.
- Send CONNECT... Message transmission
after delay.
Access to editing the attached buffer of IE(s).
Establishment source: Source to be connected in the switched
B channel(s) during the establishment state of the communication:
| None |
No data source connected. |
| Loop |
Data echoed TD-RD. |
| Handset |
To use the telephone handset (Speaker + Micro)
connected to the HANDSET connector.
A Cofidec resource is automatically connected and used. |
| Analog 1 |
Analog Input/Output 1 available on the I/0 connector.
A Cofidec resource is automatically connected and used.
* Not supported by Clarinet-Book USB type. |
| Analog 2 |
Analog Input/Output 2 available on the I/0 connector.
A Cofidec resource is automatically connected and used.
* Not supported by Clarinet-Book USB type. |
| BERT 511 |
Bit error rate test - 511 bits pattern. |
| BERT 511+ |
Bit error rate test - 511 bits pattern with error
counter details. |
| BERT 2047 |
Bit error rate test - 2047 bits pattern |
| BERT 2047+ |
Bit error rate test - 2047 bits pattern with
error counter details. |
| BERT 2**15 |
Bit error rate test - 32767 bits pattern. |
| BERT 2**15+ |
Bit error rate test - 32767 bits pattern with
error counter details. |
| TRANSIT |
TRANSIT interface with selection of the used
TS's. |
| TRANSDATA |
TRANSDATA interface with automatic TS switching
from/to the current interface. |
| Cofidec 1 |
Digital input/output of the Cofidec 1. |
| Cofidec 2 |
Digital input/output of the Cofidec 2. |
| Byte-TS /Wav |
Byte-TS or wav file selected from a choice list.
64 Kbits data source (as speech, ...). |
|
Source selection: For some data source types, a complementary
selection area must be accessed.
-
- Related topics:
- Q931 Simulator: sources in
Time-Slots
- ISDN Simulation: BERT source
operation
Incoming call accepted - Active state
Default behaviour: with the specification of the active
source to be connected and the data state duration parameters.
- Connect... active source:
Source to be connected in the switched B channel(s) during the active
state of the communication:
- Data state duration: If this duration expires, the call
is automatically cleared (an empty field means an infinite value of
time).
Downloaded behaviour: The active source to be
connected and the data state duration can be defined
in the User-User IE of the incoming SETUP by a character string under
the following conditions:
- String structure: <ACTIVE SOURCE > <DURATION> with uppercase
charracters; both fields are separated by one SPACE character.
- The string is placed at the beginning of the "User information"
field. It may be followed by comments, provided that a * character separator
is added.
- [d] optional data state duration: If this duration expires, the call
is automatically cleared.
- OUTj, COMj as outgoing communication
n° j.
| User-User
IE string |
Equivalence
in Clarinet dialogue |
| NONE [d] |
None |
| LOOP
[d] |
Loop |
| HANDSET [d] |
Handset |
| ANALOG1
[d] |
Analog
1 |
| ANALOG2 [d] |
Analog 2 |
| BERT9
[d] |
BERT
511 |
| BERT9+ [d] |
BERT 511 + |
| BERT11
[d] |
BERT
2047 |
| BERT11+ [d] |
BERT 2047 + |
| BERT15
[d] |
BERT
2**15 |
| BERT15+ [d] |
BERT 2**15 + |
| TRANSIT
n [d] |
TRANSIT
<TSn> |
| TRANSDATA [d] |
TRANSDATA |
| COFIDEC1
[d] |
Cofidec
1 |
| COFIDEC2 [d] |
Cofidec 2 |
| X25DATA [d] |
Data x25 simulator |
| PROGRAM [d] |
Data user program |
| OUTj [d] |
Outgoing call w/o TS
switching |
| COMj [d] |
Outgoing call with TS
switching |
|
Send INFORMATION... An optional sequence of INFORMATION messages can be
automatically transmitted during the Active state.
Incoming call accepted - Call clearing
With the following steps in sequence:
- If normal clearing, Send DISC/RELEASE:
Message transmission, depending on which party clears the call.
Access to editing the IE buffer attached to the DISCONNECT message.
- If resource unavailable, Send DISC/RELEASE:
Message transmission if resource unavailable (as channel or data source).
Access to editing the attached buffer of IE(s).
Copy/Paste functions
The Copy ISDN IE buffer and Paste ISDN IE buffer
functions allow you to duplicate the contents of a particular message
to an other one (in the same profile or a different one).
|