ISDN Signalling Behaviour: Responder Default Data Source
The type of selection conditions listed in the left hand side area depends
on the by IE selection.
No:
A selection between several sources is possible according to conditions
defined on the called number of the incoming call.
Yes:
A selection between several sources is possible according to whether
an IE with a particular content is present in the SETUP message of the
incoming call.
Called number condition
The Called number conditions are
checked in the order of definition of the lines and the source corresponding to the first
satisfied condition is connected.
- an empty condition on a line implies the connection of the source defined on
this line for all the communications which have not checked the conditions of the previous
lines.
- the complete definition of all the lines implicitly causes a connection to the None
source for the communications which do not fulfil any of the Called number conditions.
If called number
of incoming call is: The Called number,
included in the signalling of the incoming communication, defines the connection
condition of the data source defined on the same line.
then, Connect data source: See the list
of data sources.
Active source used for the incoming communication if the called number
defined on the same line matches the received called number. Source to
be connected in the switched B channel(s) during the active state of the
communication.
IE condition
The IE conditions are checked in the
order of definition of the lines and the source corresponding to the first satisfied
condition is connected.
- an Any IE condition on a line implies the connection of the source defined on
this line for all the communications which have not checked the conditions of the previous
lines.
- the complete definition of all the lines implicitly causes a connection to the None
source for the communications which do not fulfil any of the IE conditions.
If IE present in incoming
SETUP: The IE precisely specified and
included in the SETUP message of the incoming communication defines the connection
condition of the data source defined on the same line.
The highlighted IE is the current one, which can be selected from a list,
or used-defined.
Access to the list of IE types for the current IE.
- Editing of the IE type
- ( / ) Any IE: Any IE can be accepted.
- (0/x) designation: The IE is selected from the list.
- (0/x) User defined ie:A type value can be manually entered. The
User defined ie string is automatically displayed if the
type value does not belong to the choice list.
Coding: To edit the content
of the current IE according to the standard encoding fields if any.
Hexa: To edit the content of the
current IE if any in hexadecimal.
then, Connect data source. See the list
of data sources.
Active source selected for the incoming communication and to be connected
if the IE defined on the same line is present in the SETUP message. Source
to be connected in the switched B channel(s) during the active state of
the communication.
| None |
No data source connected. |
| Loop |
Data echoed TD-RD. |
| Handset |
To use the telephone handset
(Speaker + Micro) connected to the HANDSET connector.
A Cofidec resource is automatically connected and used. |
| Analog 1 |
Analog Input/Output 1 available on the I/0 connector.
A Cofidec resource is automatically connected and used.
* Not supported by Clarinet-Book USB type. |
| Analog 2 |
Analog Input/Output 2 available
on the I/0 connector.
A Cofidec resource is automatically connected and used.
* Not supported by Clarinet-Book USB type. |
| BERT 511 |
Bit error rate test - 511 bits pattern. |
| BERT 511+ |
Bit error rate test - 511 bits
pattern with error counter details. |
| BERT 2047 |
Bit error rate test - 2047 bits pattern |
| BERT 2047+ |
Bit error rate test - 2047 bits
pattern with error counter details. |
| BERT 2**15 |
Bit error rate test - 32767 bits pattern. |
| BERT 2**15+ |
Bit error rate test - 32767
bits pattern with error counter details. |
| TRANSIT |
TRANSIT interface with selection of the used
TS's. |
| TRANSDATA |
TRANSDATA interface with automatic
TS switching from/to the current interface. |
| Data user program |
To enable the use of the Data user program as
specified in the Data User Program
panel. |
| Cofidec 1 |
Digital input/output of the
Cofidec 1. |
| Cofidec 2 |
Digital input/output of the Cofidec 2. |
| Data X25 simulator |
To enable the use of the X25 call simulator as
specified in the Data Call simulator
panel. |
| Byte-TS /Wav |
Byte-TS or wav file selected from a choice list.
64 Kbits data source (as speech, ...). |
| Data FR simulator |
To enable the use of the Frame Relay call simulator
as specified in the Data Call simulator
panel. |
| Data IP simulator |
To enable the use of the IP call simulator as
specified in the Data Call simulator
panel. |
| Outgoing call |
Launching of an outgoing communication triggered
by an incoming communication: see attached configuration choice
list.
The relevant outgoing communication is pre-defined in the Generator
behaviour, must be selected active and the Starting
delay must be an empty field.
The outgoing SETUP is sent after the Delay
before CONNECT. |
| PESQ |
Wav file selected from a choice list ( 64 Kbits
data source).
PESQ measurement is carried out on the Tx/Rx data flows at the
end of the profile execution according to the following settings:
- Analog properties set
in the Protocol filter defined with in the profile
- configuration file set as WI_ANALOG by Clarinet-Init
|
|
Source selection: For some data source types, a complementary
selection area must be accessed.
| Triggering on the same
Clarinet interface |
| Any com+B |
The first selected and available
outgoing communication is automatically launched. The B channels
of the two communications are connected together. |
| Com i+B |
The outgoing communication
n° i is launched. The B channels of the two communications
are connected together. |
| Any com |
The first selected and available
outgoing communication is automatically launched. The B channels
of the two communications are independent. The incoming communication
is connected to active source None. |
| Com i |
The outgoing communication
n° i is launched. The B channels of the two communications
are independent. The incoming communication is connected to
active source None. |
Triggering on a twinned Clarinet
interface using the TRANSIT port: Possible pairs of Clarinet
interfaces managed by the same profile can be used depending
on their number (1 and 2, 3 and 4, 5 and 6).
Then the 2 Clarinet TRANSIT connectors must be linked together
(cross connection). |
| Any comX+B |
The first selected and available
outgoing communication for the twinned Clarinet interface
is automatically chosen. The B channels of the two communications
are connected together. |
| ComX i+B |
The outgoing communication
n° i of the twinned Clarinet interface is launched. The
B channels of the two communications are connected together. |
| Any comX |
The first selected and available
outgoing communication for the twinned Clarinet interface
is automatically launched. The B channels of the two communications
are independent. The incoming communication is connected to
active source None. |
| ComX i |
The outgoing communication
n° i of the twinned Clarinet interface is launched. The
B channels of the two communications are independent. The
incoming communication is connected to active source None. |
|
-
- Related topics:
- Q931 Simulator: sources
in Time-Slots
- ISDN Simulation: BERT source
operation
|