ISDN S0-T0 Interface Options

Generic options: Options for the Clarinet interface (whichever emulation mode is used)

  • Power source 1 monitoring: To monitor the phantom power source.
  • Power source 2 monitoring: To monitor the auxiliary power source.
  • 100 ohms termination on bus: To connect 100 Ohms terminations on the bus.
  • Multi-frame: Multi-frame management (bits Fa and N) defined in paragraph 6.3 of the I430 recommendation.
  • Level 1 measurement, one option must be selected:
    • No measurement: no test.
    • Send single zeros: Generation of calibrated pulses on the interface (monitoring must be off).
    • Send continuous zeros: Generation of calibrated pulses on the interface (monitoring must be off).

User specifications: Options to be used if the Clarinet interface emulates a User side.

  • High priority class: To select High Priority Class.
  • T3 time-limit: Value of T3 time-limit defined in the I430 recommendation.
    If it is equal to 0, the time-limit is not used.

Network specific options: Options to be used if the Clarinet interface emulates the Network side.

  • Short passive bus, for bus configuration:
    • Yes: Short passive bus mode.
    • No: Self-adapting bus mode.
  • Connect power source 1 on bus: To connect the external power source 1 on the bus.
  • Invert polarity on power source 1: To invert the polarity of the external power source 1.
 