IP Profile Editor: H323 Responder
RAS: Access
to the RAS settings specific to the current incoming call as admission,
... (used only if H225.0 RAS is initialised). Call establishment: With the following step in
sequence in reference to H323 emulator
configuration:-
- Send connect after: Delay before sending the
CONNECT message (if to be sent), starting from the reception of the
incoming SETUP message.
An empty field denotes an infinite delay.
- CONNECT...: Message
transmitted.
Click on the message to edit the attached buffer of IEs.
Call active: You can specify the active source
to be connected, transmission mode and the resulting duration parameters:-
- Active source: Data source to be connected:
- None: No data source.
- RTP Simulator: An RTP profile must be
selected from the list.
- PESQ: Wav file selected from the list.
PESQ measurement is carried out on the Tx/Rx RTP data flows at the
end of the execution of the profile, according to the following
settings:-
- Analog properties (with Auto
mode) set in the Protocol filter defined within the profile.
- Configuration file set as WI_ANALOG by Clarinet-Init
- Source selection: For some types of data source,
further selection must be made from the lists that are defined in the
IP Profile Editor.
- Transmission mode:-
- Send continuously for a duration:
The call is automatically cleared when the duration
expires.
An empty field denotes an infinite duration.
- Send number of time(s) and clear after delay:
The selected data source is transmitted, for the specified number
of times, and the call is automatically cleared after the delay
has expired.
An empty field denotes an infinite delay.
Call clearing: With the following step in sequence:-
- If normal clearing, send RELEASE COMPLETE...:
Message transmitted.
Click on the message to edit the attached buffer of IEs.
- If resources unavailable, send RELEASE COMPLETE...:
Message transmitted.
Click on the message to edit the attached buffer of IEs.
|