ATM Signalling Behaviour: Responder Default Data Source
The type of selecting conditions listed in the left hand side area depends
on the by IE selection.
No:
A selection between several sources is possible according to conditions
defined on the called number of incoming the call.
Yes:
A selection between several sources is possible according to whether
an IE with a particular content is present in the SETUP message of the
incoming call.
Called number condition
The Called number conditions are
checked in the order of definition of the lines and the source corresponding to the first
satisfied condition is connected.
- an empty condition on a line implies the connection of the source defined on
this line for all the communications which have not checked the conditions of the previous
lines.
- the complete definition of all the lines implicitly causes a connection to the None
source for the communications which do not fulfil any of the Called number conditions.
If called number
of incoming call is: The Called number,
included in the signalling of the incoming communication, defines the connection
condition of the data source defined on the same line.
then, Connect data source:
Active source used for the incoming communication if the called number
defined on the same line matches the received called number.
None: (No source is connected) is the only choice.
IE condition
The IE conditions are checked in order of definition of the lines and the source
corresponding to the first satisfied condition is connected.
- an Any IE condition on a line implies the connection of the source defined on
this line for all the communications which have not checked the conditions of the previous
lines.
- the complete definition of all the lines implicitly causes a connection to the None
source for the communications which do not fulfil any of the IE conditions.
If IE present in incoming
SETUP: The IE precisely specified and
included in the SETUP message of the incoming communication defines the connection
condition of the data source defined on the same line.
The highlighted IE is the current one, which can be selected from a list
of choices, or user-defined.
Access to the list of IE types for the current IE.
- Editing of the IE type
- ( / ) Any IE: Any IE can be accepted.
- (0/x) designation: The IE is selected from the list
of choices.
- (0/x) User defined ie: A type value can be manually
entered. The User defined ie string is automatically displayed
if the type value does not belong to the list of choices.
Coding: To edit the content
of the current IE according to the standard encoding fields if any.
Hexa: To edit the content
of the current IE if any in hexadecimal.
then, Connect data source:
Active source selected for the incoming communication and to be connected
if the IE defined on the same line is present in the SETUP message.
None: (No source is connected) is the only choice.
|