How to Aggregate TSs over an E1/T1 TrunkClarinet-system supports monitoring and simulation on a group of Time-Slots on an E1 or T1 interface:
Connecting the unitSee the pictures in the 'How to connect E1/T1 interface to Clarinet-Book USB' page. Setting the test conditions for BOP monitoringA new profile can be created with the Wizard from the Template list by selecting:
Profiles resulting from the wizard are ready for BOP monitoring over B channel number 1. Example: Modifications to monitor Frame-Relay over 4 TS'sThe TS's are supposed to be 2, 4, 5, 6 for an aggregated Data Link at 256 kbit/s. In the profile go to Interface-Spec... ->Data Link and select:
Warning: Any number and value of TS can be selected but the same number of TS's must be selected in both TD and RD. Setting the test conditions for BERT simulationA new profile can be created with the Wizard from the Template list by selecting:
Profiles resulting from the wizard are ready for Bert Simulation over B channel number 1. When Running the profile, the Bert Measurement has to be launched through Manual commands:
Example: Modifications to simulate BERT over 30 TS's of E1(The TS's are supposed to be (1-15 + 17-31) for an aggregated Data Link at 1920 kbit/s. In the profile go to Interface-Spec... ->Data Link:
|
|