How to Simulate V5.1 - AN side over E1 Interface
Simulation of V5 AN equipment is one of the features of the Clarinet
Run-Time.
Connecting the unit
The Clarinet Book USB E1/T1 which simulates the AN side
in front of an LE, uses the B port 'From LE'.
The Clarinet Book can be connected to the E1 interface in:-
Creating the profile for V5.1 AN simulation
A new profile can be created from a template, using the wizard, by selecting:-
- Profile=>New=>V5...
(see: building).
- Profile with a description, including ISDN,
Simu, AN, PH=E1 SL=V5.1
- Filter with a description, including SL=
V5
Example using the wizard:-
- Profile=>New=>V5.x=>v51_simu_an_e1.acp=>Filter=>v5.acf
The profile created by the wizard is ready for monitoring in the C channels
over time slot 16 and 15.
- Modifications to apply to the profile relating to the physical interface:-
- E1 options: CRC4 multi-frame is normally used
over V5 (selected by default).
Deselect it if not used (Interface Specs=>Link=>Options).
- Modifications to apply to the profile relating to PSTN signalling:-
- Changing the dialled number: Generator=>Comm1=>Edit=>Called
Party Number=>Coding.
Saving the profile under a new name:-
- Profile=>Save as=>filename.acp.
Running the profile
To launch the profile:-
- Select Profile=>Run or click
on the
button. You will be able to select the name of the profile (see
running
a profile).
- The Event Editor window is opened automatically.
To stop the profile:-
- Click on the
button (see: stopping
a profile).
- The Event Editor window is automatically closed.
Troubleshooting over PRI
- No messages are displayed in the Event Editor window: Check whether
there are any alarm indication such as ' -+ FL' or
'++FL' meaning that no signal is detected.
- The protocol messages are displayed in the wrong directions: The E1
pair connected to the A and B port are the wrong way round.
|