Event information
|
Date:
|
Date of the event (end of BOP frame) in the
format: hh:mm:ss/xxx.y |
|
N
|
The interface number which identifies the
Clarinet-interface connected to the host. |
Link type
|
- TS: Signalling Link Transmit
direction
- RS: Signalling Link Receive direction
- TD: Data Link Transmit direction
- RD: Data Link Receive direction
|
Dx
|
The decoding level as specified in the
filter (protocol stack). |

|
Protocol fields
|
X25-Packet
|
(Address) <PDU type> Ctrl-1
[nnnn]
Ctrl-2 |
 |

|
Data field
|
Raw data
field displayed if no upper layer protocol is defined in the filter.
The display mode can be Hexa, Ascii or Ebcdic as specified in the
filter.
User data field, if present, is part of data field and displayed after
the string User data. |
 |

|
(Address)
|
In the following format: (x,yyy) |
|
x
|
LC group number. |
|
yyy
|
LC number. |
 |
<PDU_type>
|
Type of packet. |

|
Ctrl-1
|
Control field in the format A:x
D:x or Q:x
D:x M:x
PR:xxx PS:xxx
: |
|
A:x
|
Value of A bit (0 if nonTOA/NPI address
format or 1 if TOA/NPI address format). |
|
D:x
|
Value of Delivery confirmation bit
(0 or 1). |
|
Q:x
|
Value of Qualifier bit (0 or 1). |
|
M:x
|
Value More data bit (0 or 1). |
|
PR:xxx
|
Value of PR (packet receive sequence
number). |
|
PS:xxx
|
Value of PS (packet send sequence
number). |
 |
[nnnn]
|
Length of the data field. |

|
Ctrl-2
|
Optional complementary fields are displayed according
to the display mode selected in the filter :
| Field |
Identified mode |
Detailed mode |
| Cause: |
hex |
bij
dec meaning |
| Diagnostic: |
hex |
bij
dec meaning |
| Called:/Calling: |
digits |
digits |
| User facilities: |
sequence |
xx:
designation value
...... |
|
|
hex
|
Value in hexadecimal. |
|
bij
|
Bit configuration within the relevant
octet. |
|
dec
|
Value in decimal. |
|
meaning
|
Meaning attached to the value, according
to the standard. |
|
digits
|
Number digits. |
|
sequence
|
Content of the buffer of User facilities
in hexadecimal. |
|
xx
|
User facility code. |
|
designation
|
Designation of the relevant User
facility according to the standard. |
|
value
|
Content of the relevant User facility
in hexadecimal. |