Initialization of Clarinet-Book USB Ethernet 10/100
| L1 |
The LED L1 (Red color) reflects the battery
and charger state:
- Continuously ON: charge process completed or interrupted
- 2 flashes: high current charging
- 1 flash: trickle charge
The LEDs flash briefly every 3-4 seconds.
The charge process is halted:
- When the CLARINET is running a profile
- When the battery is fully charged
- During the CLARINET initialization (about 30s after power-on,
or loader op.)
Normal operating state is "continuously ON".
If the LED is continuously OFF, the battery is flat
|
ID
(Coding wheel) |
Several Clarinet modules connected to the PC must have different
ID's (from 1 to 7), set by the coding wheel. After changing
the value selected on the coding wheel the Clarinet Loader must
be executed. |
| ON |
Pushing the button (through the hole) resets the Clarinet-Book
unit. |
| Power |
To connect the external Power-adapter unit. |
| USB |
To connect the USB cable (type B) |
| SIG |
For maintenance purposes |
| L2 |
The LED L2 (green) reflects the USB state (configuration
and power):
- 1 flash: USB OK - powered by USB
- 2 flashes: USB OK - powered by external power
adapter
- 3 flashes: USB OK - powered by battery
- 4 flashes: USB unconfigured - powered by external power
adapter
- 5 flashes: USB unconfigured - powered by battery
The LEDs flash briefly every 3-4 seconds.
Normal operating states are states 1 or 2.
|
|
| 100 M |
ON= running a profile with the 100 M mode selected. |
| RJ 45 selection |
ON= running a profile with the RJ45 mode selected. |
| AUI selection |
ON= running a profile with the AUI mode selected.
The Clarinet-Book can be connected to a 10B2 BNC connector
by using:
- An external transceiver AUI-10B2
- The external Power-adapter unit of the Clarinet-Book which
provides the power to the transceiver
|
| Ethernet interface |
The LEDs display the interface activities:
- TX: data to be transmitted to the Output
direction
- RX: data received on the Input direction
- LINK: "Good link" Link integrity
status.(Twist Pair)
- POL: "Polarity" Detection of
Pulse with reverse polarity (Twist Pair)
- COL: Collision Detection (Twist Pair
or AUI)
|
|
| Unit Power |
The Clarinet module connected to the PC can be powered by
:
- a set of batteries normally placed inside the module.
- the USB connection to the PC (or a HUB device).
- an external power supply unit.
When CLARINET is only powered by USB (bus-powered
device), only trickle charging is done.
As the NiMH batteries can be deteriorated by overcharging,
a full charge process is done only if the battery is detected
low at initialization.
To force a full-charge process, select 0 on the coding wheel
and connect the wall adapter.
|
| Startup |
CLARINET is started up when power is detected on USB bus during
the PC power-on sequence, or when an USB connector is plugged.
CLARINET automatically shut-down when USB is suspended (PC
powered off, or USB disconnected) after a short delay:
- 30 s if the device has been configured via USB
- 3 ' if the device is unconfigured, to give time to the
PC to boot
If CLARINET is shutdown with the ON button, the USB cable
must be unplugged-plugged to restart it.
|
|
|