Events: BOP

Event structure Explanation of protocol events.

BOP decoding Using the Clarinet Event-Editor with an appropriate filter.

Protocol stack Defining a list of protocols used in the current filter.

Standards
  • ISO 4335
 

Options Changing the display conditions in the current filter.

Clarinet Event-Editor: BOP decoding

bop_isdn_decod.gif (9572 octets)

Event information Date Date of the event (end of BOP frame) in the format: hh:mm:ss/xxx.y  
N The interface number which identifies the Clarinet-interface connected to the host.
Link type
  • TS: Signalling Link Transmit direction
  • RS: Signalling Link Receive direction
  • TD: Data Link Transmit direction
  • RD: Data Link Receive direction
Dx The decoding level as specified in the filter (protocol stack).

Protocol fields BOP <BOP type> <flag counter>    [nnnn]

Data field Raw data field displayed if no upper layer protocol is defined in the filter.
The display mode can be Hexa, Ascii or Ebcdic as specified in the filter.
 

BOP Protocol fields

<BOP type>
  • Frame: Valid frame with correct CRC calculation result.
  • Beginning of Idle state (1 permanent).
  • End of Idle state (1 permanent).
  • Abort frame.
  • Crc error: Frame with false CRC calculation result.
<flag_counter> If normal frame, the numbers of flags from the previous BOP event in the same direction.
[nnnn] If normal frame, the numbers of octets of the information field. The length does not include the 2-octet CRC.

Protocol stack applied

bop_isdn_stack.gif (7270 octets)

 