Initialization of Clarinet-Book USB Vseries
| |
 |
| L1 |
The LED L1 (Red colour) reflects the battery and
charger state:
- Continuously ON: charge process completed or interrupted
- 2 flashes: high current charging
- 1 flash: trickle charging
The LEDs flash briefly every 3-4 seconds.
The charge process is halted:
- When the CLARINET is running a profile
- When the battery is fully charged
- During CLARINET initialization (about 30s after power-on,
or loader op.)
Normal operating states is "continuously ON".
When the LED is continuously OFF it means the battery is flat
|
ID
(Coding wheel) |
Several Clarinet modules connected to the PC must
have a different ID's (from 1 to 7), set by the coding wheel.
After changing the value selected on the coding wheel the Clarinet
Loader must be executed. |
| ON |
Pushing the button (through the hole) resets the
Clarinet-Book unit |
| Power |
To connect the Power-adapter unit |
| Handset |
RJ11 to connect a regular phone handset |
| Transdata |
15 pin SUB-HD to connect the Trandata link |
| USB |
To connect the USB cable (type B) |
| SIG |
For maintenance purposes |
| L2 |
The LED L2 (green) reflects the USB state (configuration
and power):
- 1 flash: USB OK - powered by USB
- 2 flashes: USB OK - powered by external power
adapter
- 3 flashes: USB OK - powered by battery
- 4 flashes: USB unconfigured - powered by external power
adapter
- 5 flashes: USB unconfigured - powered by battery
The LEDs flash briefly every 3-4 seconds.
Normal operating states are states 1 or 2.
|
|
| |
 |
|
The Clarinet-Book detects if a suitable cable is connected
to one of the HD60 sockets:
- If so, only the relevant LED is turned on
- Otherwise, the 4 LEDs are all turned on.
An 'Error cable' message is displayed in the event file.
|
| V24 |
ON= running a profile with the V24 interface selected in Interface-specs/Physical |
| V35 |
ON= running a profile with the V36 interface selected in Interface-specs/Physical |
| V36 |
ON= running a profile with the V36 interface selected in Interface-specs/Physical |
| X24 |
ON= running a profile with the X24/V11 interface selected
in Interface-specs/Physical |
|
| Unit Power |
The Clarinet module connected
to the PC can be powered by :
- A set of batteries normally placed inside the module.
- The USB connection to the PC (or a HUB device).
- An external power supply unit.
When the CLARINET is only powered by USB
(bus-powered device), it is only trickle charged.
As the NiMH batteries can be deteriorated by overcharging,
a full charge process is only done if the battery is detected
low at initialization. To force a full-charge process, select
0 on the coding wheel and connect the external power adapter.
|
| Startup |
THe CLARINET is started up when
power is detected on USB bus during the PC power-on sequence,
or when a USB connector is plugged in.
The CLARINET automatically shuts-down when USB is suspended
(PC powered off, or USB disconnected) after a short delay:
- 30 s if the device has been configured via USB
- 3 ' if the device is unconfigured, to give time for the
PC to boot
If CLARINET is shutdown with the ON button, the USB cable
must be unplugged-plugged to restart it.
|
|
|